WARNING: If you have poor grounding, poor connections or broken wires, your Fence Minder™ will NOT be able to detect problems on the fence line. Alarm Operation depends on good grounding and correct fence wiring.

* A siren may be set for continuous alarm, or for intermittent operation to comply with local noise pollution regulations (either a 2 minute Siren Alarm every 15 minutes, or a 1 minute Siren Alarm every 30 minutes - see Appendix A). A flashing light can signal an alarm condition. An auto-dialer and telephone service can provide an immediate phone alert to your home, work or neighbor.

* The Reset Switch can be used at any time to restart operations and to reset an alarm, (if pressed for less than a second). If pressed for more than a second (and then released), the Reset Switch will cycle through any connected alarm devices to verify their correct operation - each alarm device will come on for two seconds and then shut off.

* When first turned on, the Fence Minder™ takes 60 seconds to compare the actual fence voltage to pre-set minimum conditions. The Minder™ then continuously monitors and compares the fence voltage to a moving average. If the Minder™ is restarted following an alarm, the Minder™ will, again, first take about 30 seconds to verify the fence meets minimum conditions. If the alarm re-occurs, troubleshooting will be required.