- At night you can see sparking from electrical arcing. Mark any
arcing points so you can fix problems in daylight.
Step3.
Remove any weeds, bushes or debris which touches the fence.
Step
4. Follow the testing and diagnostic procedures in your Electrobraid
Fence Installation Manual.
Please
do not hesitate to call our Toll Free, 7 day a week (7am-7pm Central
Time), Technical Support at 1-888-430-3330.
5.5
Ground Voltage more than 300 volts
Step1.
Check for anything, including tall weeds or bushes that might electrically
connect a hot strand of Braid™ to your grounded strand.
Step
2. Wet the soil around your ground rods, let the water soak in and
then re-test the voltage. If wetting reduces the voltage to below
300 volts, you need to add ground rods to improve the grounding system.
Look for permanently moist soil anywhere along the fence line and
connect the new ground rods to your grounded strand of Braid™.