1)
Disconnect the energizer from the fence.
2) Connect the energizers to the Fence Minder.
3) SW! switches 4,5, & 6 MUST be set to OFF
4) Using
a small length of wire (5" to 6"), connect the ENABLE terminal to
the (-) battery terminal on the Fence Minder™.
5) Power the Fence Minder™.
6) Press the Reset button.
7)
Remove the small length of wire from the terminals.
The
yellow LED will remain lit until your energizer's voltage Count is
saved to EEPROM after which the unit will resume normal operation.
The yellow LED should blink in rhythm with the energizer pulse; if
not, please call us and let us help you trouble shoot the problem.
A.2.3
DEBUG MODE
The amount of data output on the serial RS232 port when the Fence
Minder™ is running is set using SW1-7, SW1-8. This is only to be used
by a trained technician.
|
Setting
|
Low
|
.2.
|
.3.
|
High
|
|
SW1-7
|
Off
|
Off
|
On
|
On
|
|
SW1-8
|
Off
|
On
|
Off
|
On
|
Default settings are SW1-7 Off; SW1-8 On
A.3
DEFAULT SETTINGS FOR SWITCH BANK SW-2 (oriented per the
schematic):

Note: The white block indicates the position of the
switch
A.3.1
UN-INTERRUPTED ENERGIZER OPERATIONS:
SW2-1
is set to Off: the energizer power will be turned off by an
Alarm Type 1 (a sudden drop of voltage).
Default
settings is OFF