A.3.2
SAMPLE SIZE OF RUNNING AVERAGE
This is the number of samples used to calculate the running average.
A low value will increase sensitivity to changes from the running
average. The setting uses SW2-2 and SW2-3.
|
Setting
|
Low
|
..
|
..
|
High
|
|
SW2-2
|
Off
|
Off
|
On
|
On
|
|
SW2-3
|
Off
|
On
|
Off
|
On
|
|
Value
|
10
|
20
|
40
|
60
|
Default setting is 10
A.3.3
RAIN TRIGGER LEVEL
This is a threshold (in percentage level) that will determine the
sensitivity change appropriate to a switch to "Rain" Mode. The setting
uses SW2-4 and SW2-5.
|
Setting
|
Low
|
..
|
..
|
High
|
|
SW2-4
|
Off
|
Off
|
On
|
On
|
|
SW2-5
|
Off
|
On
|
Off
|
On
|
|
Value
|
101%
|
103%
|
105%
|
107%
|
Default
setting is 107%.
A.3.4
RAIN SENSITIVITY CHANGE
This is the percentage to be added to the sensitivity setting for
normal operations to deal with a "Rain" event. The setting uses SW2-6
and SW2-7.
|
Setting
|
Low
|
..
|
..
|
High
|
|
SW2-6
|
Off
|
Off
|
On
|
On
|
|
SW2-7
|
Off
|
On
|
Off
|
On
|
|
Value
|
1%
|
2%
|
3%
|
5%
|
Default
setting is 1%
A.3.5
INTERMITTENT SIREN OPERATION DURING ALARM MODE
SW2-8
is set to ON: siren will be on for 1 minute (continuous)
every 30 minutes.
SW2-8 is set to OFF: siren will be on for 2 minutes (continuous)
for every 15 minutes.
Default
setting is OFF.
NOTE:
The Fence Minder WILL NOT FUNCTION with out the cover in place.