APPENDIX
C: TECHNICAL SPECIFICATIONS
C.1 Compliance
to Standards
CSA
C22.2 No. 205-M1983 Signal Equipment
Consumer and
Commercial Products
CSA
C22.2 No. 0.4-M1993 Bonding and Grounding of
Electrical Equipment
Protective Grounding
C.2 Operating
Temperature Range: -20 C to + 60
C. C.3
Input Power Supply
C.3.1
100V - 125V AC / 60 Hz (mains supply)
C.3.2 8 to 16 V DC (battery)
C.4 High
Voltage Input - Is designed to be connected ONLY to a fence energizer
output.
Impedance: 20,000 ohm.
Pulse Interval: 0.9 - 1.4 seconds
Pulse Energy: max 10 Joules
Pulse Voltage: max 11,000 V
C.5 Rating
of the switched AC power supply outlet for the fence energizer.
Voltage: same
as input power supply
Current: 1
A continuous, with fuse protection
C.6 Rating
of the switched DC power supply output for the fence energizer.
Voltage: same as input power supply
C.3.2
Current: 1.35 A continuous, with fuse
protection
C.7 Light
Alarm Output: Switched / Continuous on until reset.
Voltage: same as input power supply C.3.2
Current: 0.65 A continuous, with fuse protection
C.8 Siren
Alarm Output: Switched / Limited time operations due to regional and
local audible noise pollution regulations.
Voltage: same as input power supply C.3.2
Current: 0.65 A continuous, with fuse protection
C.9 Auto-Dialer/Wireless
Modem Power Supply: Switched / Continuous on until reset.
Voltage: same as input power supply C.3.2
Current: 0.65 A continuous, with fuse protection