C.10 RS232
serial communication port. All I/O's are short-circuit protected and
PC compatible.
Rx: input
receive line (2.2k impedance / -15V to +15V)
Tx: output transmit line (0 to 5 V / 10mA drive capability)
INT: interrupt input (2.2k impedance /-15V to +15V)
Enable: 2.2k pull-up/transistor output (100mA drive capability)
At present, the Rx and Enable lines are inactive.
Tx serial output: 9,600 baud, 8, N, 1.
C.11 Enclosure:
Made
of polymeric material compliant with UL 94V0 flammability standard.
Offers protection from dust and water splash. The Fence Minder™ operates
only indoors.
NOTE:
For outside installation, a suitable enclosure must be used.
The mechanical
assembly is resistant to vibrations and shock as described in Chapter
8 and 27 of UL69.
Has mounting bracket for wall installation.
C.12 Grounding
and other Protective Features:
The unit
has earth ground protection and safe gap separation between the high
voltage input coming from the energizer and the rest of the circuitry.
All the exposed Fence Minder™ terminals are stainless steel and operate
with voltage less than 16 V DC to ground. Each unit is tested for
safe insulation between mains (120VAC plug) and these terminals.
The connector can accommodate wires between 12 - 24 AWG secured with
screws for protection against bad contacts and loosening under shocks
and vibrations.
All output circuits are fuse protected as described above.