lead
from the positive (+) terminal on the alarm device to the positive
(+) terminal on the Fence Minder™. Attach a negative lead from the
alarm device to the negative (-) terminal on the Fence Minder™. When
hooking up an Auto-dialer, follow the manufacturer's instructions.
For continuous siren alarm, connect the siren to the "light" alarm
terminal on the Fence Minder™. For intermittent siren alarm, connect
the siren to the "siren" alarm terminal. Note that two alternative,
intermittent alarm settings are available: see Appendix A - Changing
dip switch settings.
6. Plug
the 110 volt power cord of the Fence Minder™ into a wall outlet.
7. Ensure
the two wires of the power supply are firmly attached to the battery
terminals on the Fence Minder™ (polarity is not important) and plug
into a wall outlet.
8.
To Start of the Fence Minder™ operation: Press and hold the Reset
Button until you hear the Minder™ reset, and then release the button.
The Fence Minder™ will go through a 60 second evaluation cycle while
it checks the status of the fence. The green light should show solid
green, which means the power is on. The yellow light will start solid
yellow until it begins to flash in rhythm with the pulse from the
energizer. The red light will remain off.
NOTE:
The cover of the Fence Minder™ must be in place or it will not function.