Previous Home Next

the wire lead of the voltmeter to the (-) terminal of the energizer. If less than 5,000 volts, there is a problem with the energizer.

4. If the energizer is O.K., turn it OFF before you reconnect the two lead-out wires to the energizer, then turn the energizer back ON.

5. Now read the voltage on each strand of your fence near where the energizer is connected to the fence.  Apply the ground pin on the voltmeter to the second-from-the-top grounded line and apply the Voltmeter to each of the other electrified Positive lines, one after the other. You should read at least 5,000 volts, there is a problem with the lead-out wire or you have crossed wires during installation.

6. Now go to the point of your fence which is most distant from your ground system. First, read the voltage between the second-from-the-top grounded line and each of the other electrified fence lines to confirm that the fence is wired properly with no electrical shorts. Then and most importantly, check the voltage between each electrified fence line and the soil under the fence. Place the ground pin on the voltmeter about a half inch into the soil and test the actual voltage of each positive line. If less than 5,000 volts, you have a problem with your ground system. See instructions on how to "Test the Earth Return System".

7. Finally, check the voltage to the soil at any high points or dry areas to make sure you are getting at least 5,000 volts. If less than 5,000 volts, you will need to install additional ground rods.

REMEMBER: ALL READINGS SHOULD BE OVER 5,000 VOLTS

If any reading is less than 5,000 volts, you need to troubleshoot and fix the problem. If you can't fix the problem, call us at 1-888-430-3330 and let us help you.

Testing your Earth Return System of your Fence

1 Turn the fence energizer OFF.

2. 300 or 400 feet from the fence energizer, create a short circuit of the current in the fence by laying two or three steel stakes or lengths of pipe against the lowest, hot line of the fence, preferably where the ground is damp. DO NOT ALLOW CONTACT WITH THE GROUNDED SECOND-FROM-TOP LINE OF BRAID - it is important that the electrical current flow freely from the electrified fence lines into the Earth Return System.

3. Turn the fence energizer ON.

Call us Toll Free: 1-888-430-3330